Entradas

Why Filter? Six Basic Contaminants in Fluid

Imagen
Who wants contaminated water? Testing water and fluids for contaminants is important because there are six basic types of material that can make it murky (or simply mysterious). Thermo Scientific Nalgene Analytical Filter Units 1. Suspended Particles Sand, silt, leaves, etc. Measure these with a turbidity meter. Remove them with filters with pore sizes of 1 to 20 microns Colloidal particles (What? These are small particles 0.01 to 1.0 micron so fine they do not settle without prior coagulation). Remove them with anion exchange resin (DI), ultrafiltration, reverse osmosis, and distillation 2. Dissolved Inorganics  like silicates, chlorides, fluorides, bicarbonates, sulfates, phosphates, nitrates, and ferrous compounds. Measure these with a conductivity meter. Remove them with deionization and reduce them by reverse osmosis and distillation 3. Dissolved Organics  include proteins, alcohols, chloramines, and residues of pesticides, herbicides, and detergent...

Philips HD-15 Shared Ultrasound System 2012

Imagen
Cardiac and OB/GYN Applications, Software Level 3.0.1, DICOM, Printer, Under Service Contract with Philips, Transducers, C5-202H55X, D2.0ccwBO13RK, L12-3 Linear 21475ABOGT2, S5-2BOC4PH, C8-4V, 120v, 50/60Hz   Please contact us for pricing.     Leasing Opportunities.  Please click here! https://www.facebook.com/groups/medicalequipment/

Ziehm C-Arm

Imagen
Ziehm Vista Plus , año 2007      "as is, working condition"     Opciones:  Peds/Extremities, Spine, Chest

MUEBLES VETERINARIOS

Imagen
  Jaulas mascoteras y de corta estancia de acero inoxidable y cristal   Baterias de diferentes diseños y medidas de acero inox y pisos sanitarios con forro de pvc Mesas veterinarias de cirugía Mesa eléctrica y de baterías para exploración veterinarias

Troubleshooting Gas Mass Flowmeters

Imagen
Gas mass flowmetersonly work with dry gasses. Normally the gasses are pure as well. If the gas contains too much moisture, an errant reading will occur. In this case a gas dryer is needed. What else may be happening when your gas mass flowmeter is not operating properly? Here are some possibilities: Problem:  The reading is too high Solution:  Known as “swamping,” this happens when the flow exceeds 10% beyond the maximum-rated capacity. Lower the flow and shut system down completely to restore performance. Problem:  No display/power Solutions:  Check to make sure all cables are connected correctly and the power supply has been correctly selected according to requirements. When several meters are used on a power supply, an appropriate current rating should be selected. Possibly check for a blown fuse. Problem:  Incorrect reading Solutions: Check for any leaks in the installation plumbing. Ensure the connect...